Faculty of Medical Sciences > Radiological Physics > Research & Publication
Assessment of monitor unit limiting strategy using volumetric modulated arc therapy for cancer of hypopharynx. Physica Medica 2017; 35: 73-80.
Pre-biopsy multiparameteric MRI based risk calculator and statistical model for predicting prostate cancer in biopsy naive men with prostate-specific antigen between 4-10 ng/mL. J Mag. Reson Imaging 2017. (Accepted for publication)
Multiparametric MR can identify high grade prostatic intraepithelial neoplasia (HGPIN) lesions and predict future detection of prostate cancer in men with a negative initial prostate biopsy. Magn Reson Imaging. 2016; 34(8): 1081-1086.
Stratification of aggressiveness of prostate cancer using pre-biopsy multiparametric MRI (mpMRI). NMR Biomed. 2016; 29(3):232-8.
Comparison of treatment plans: a retrospective study by the method of radiobiological evaluation. Pol J Med Phys Eng. 2016;22(3):61-68
A pilot study to evaluate the efficacy of cerrobend shielding stents in preventing adverse radio therapeutic effects in buccal carcinoma patients. J Cancer Res Ther. 2016 Jan-Mar; 12 (1):314-7.
Evaluation of performance of algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast superposition and Convolution algorithms. J Biomed Phys Eng. 2016; 6(3):127-138.
Performance evaluation of algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast superposition and Convolution algorithms. J Biomed Phys Eng. 2016; 6(3): 127-8.
Predictive models in differentiating vertebral lesions using multiparametric MRI (mpMRI). AJNR Am J Neuroradiol 2016. (Accepted for publication)
Underdosing of the Maxillary Sinus for Small Fields used in Newer Radiotherapy Techniques: Comparison of TLD and Monte Carlo Data. J Cancer Res Ther. 2016 (Accepted for publication)
Assessment of S Values for I131 and Y90 based on the Digimouse voxel Phantom. J Cancer Res Ther. 2016 (Accepted for publication)
Small Field Depth Dose Profile of 6MV Photon Beam In A Simple Air-Water Heterogeneity Combination: A Comparison Between AAA Dose Estimation With TLD Dose Measurement. J Cancer Res Ther. 2016 (Accepted for publication)
Evaluation of AAA and XVMC algorithms for dose calculation in lung equivalent heterogeneity in photon fields: Comparison of calculated results with measurements. J Biomed Phys Eng. 2015 (Accepted for publication)
Evaluation of Electron Specific Absorbed Fractions in organs of Digimouse Voxel Phantom using Monte Carlo Simulation code FLUKA. J Biomed Phys Eng. 2016 (Accepted for publication)
Evaluation of dose perturbation at the interface of two different density medium using GAFCHROMIC film EBT2 and Monte Carlo code EGSnrc for Co‑60 beam. J Cancer Res Ther. 2015;11(4):775-9.
Dosimetric study for the development of heterogeneous chest phantom for the purpose of patient specific quality assurance. Radiat Prot Environ 2015;38(4): 139-143.
Acceptance testing and quality assurance of Simulix Evolution radiotherapy simulator. Radiat Prot Environ 2015;38(3):102-108.
Dosimetric effect of intra-fractional and inter-fractional target motion in lung cancer radiotherapy techniques. Int J Cancer Ther Oncol. 2015; 3(4):343.
Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation code FLUKA. J Biomed Phys Eng. 2015 (Accepted for publication)
Evaluation of dose calculation accuracy of various algorithms in lung equivalent inhomogeneity: Comparison of calculated data with Gafchromic film measured results. J Cancer Res Ther. 2015 (Accepted for publication)
Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study. J Biomed Phys Eng. 2015 (Accepted for publication)
Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study. J Biomed Phys Eng. 2015 (Accepted for publication)
Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study. J Biomed Phys Eng. 2015 (Accepted for publication)
High-resolution NMR spectroscopy of human body fluids and tissues in relation to prostate cancer. NMR Biomed. 2014; 27(1):80-9.
Prognostics of Cyclin‑D1 expression with chemo radiation response in patients of locally advanced oral squamous cell carcinoma. J Cancer Res Ther. 2014;10(2): 258-64
Magnetic resonance spectroscopy imaging-directed transrectal ultrasound biopsy increases prostate cancer detection in men with prostate-specific antigen between 4-10 ng/mL and normal digital rectal examination. Int. J Urol. 2014; 21(3):257-62.
A simplified technique to fabricate tissue bolus device to manage dose distribution in maxillectomy patient with orbital exenteration. J Oral Biol Craniofac Res. 2013 May-Aug; 3(2):102-4.
An epidemiological study on delay in treatment initiation of cancer patients. Health; 2012: 4(2):66-79.
A positive MRSI with negative initial biopsy may predict future detection of prostate cancer. Short communication: Ind J Urol 2012:28(2); 243-45.
A new method to correct the attenuation map in simultaneous transmission/emission tomography using 153Gd/ 67Ga radioisotopes. J Med Phys 2012;37:46-53
An investigation of a sinogram discontinuity artifact on myocardial perfusion imaging. J Nucl Med Technol. 2012;40(1):25-28.
Monte Carlo study of dosimetric parameters and dose distribution effect of inhomogeneities and source position of GammaMed Plus source. J Can Res Ther 2011;7:29-34.
Radiation exposure to nuclear medicine personnel handling positron emitters from 68Ge/68Ga generator. Ind J Nuclear Med 2011; 26: 83-87.